Showing all 11 results

Show 36

Medium voltage power cables with PVC insulation – NYSY, NAYSY – PHP 48, PHP 48-A

Standard: SRPS N.C5.220
DIN VDE 0276-620; HD 620 S2;
IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION
Conductor: multi-core, class 2,
copper: type PHP 48 (NYSY), or
aluminium: type PHP 48-A (NAYSY), according to SRPS N.C0.015, IEC 60228.

Medium voltage power cables with XLPE insulation – N2XSEY, NA2XSEY – XHP 48, XHP 48-A

Standard: SRPS N.C5.230
DIN VDE 0276-620; HD 620 S2
IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION
Conductor: multi-core conductor class 2,
copper XHP 48 (N2XSEY) or aluminium conductor XHP 48-A (NA2XSEY), according to SRPS N.C0.015, IEC 60228.

Medium voltage power cables with XLPE insulation – N2XSY, NA2XSY – XHP 48, XHP 48-A

Standard: SRPS N.C5.230
DIN VDE 0276-620; HD 620 S2
IEC 60502-2
Nominal voltage U0/U:
6/10 kV, 12/20 kV, 18/30kV, 20/35 kV
Test voltage: 21 kV, 42 kV, 63 kV, 70kV
CONSTRUCTION
Conductor: multi-core conductor class 2,
copper XHP 48 (N2XSY) or aluminium conductor XHP 48-A (NA2XSY), according to SRPS N.C0.015, IEC 60228.
Inner semi-conductive layer

Medium voltage power cables with XLPE insulation – XHE 49, XHE 49-A

Standard:
SRPS N.C5.230
DIN VDE 0276-620; HD 620 S2; IEC 60502-2
Nominal voltage U0/U:
6/10 kV, 12/20 kV, 20/35 kV
Test voltage: 21 kV, 42 kV, 70kV
CONSTRUCTION
Conductor: multi-core compacted class 2, copper XHE 49 or aluminium XHE 49-A conductor, according to SRPS N.C0.015, IEC 60228.

Power medium voltage cable with cross-linked polyethylene insulation XLPE and mechanical protection – XHE 81, XHE 81-A

Standard: SRPS N.C5.230
DIN VDE 0276-620; HD 620 S2;
IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION:
Conductor: multi-core conductor class 2,
copper XHP 81 or aluminium XHP 81-A
according to SRPS N.C0.015, IEC 60228.

Power medium voltage cable with cross-linked polyethylene insulation XLPE and mechanical protection – XHE 84, XHE 84-A

Standard: SRPS N.C5.230
DIN VDE 0276-620; HD 620 S2; IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION:
Conductor: multi-core annealed conductor
class 2, copper XHP 84 or aluminium

Power medium voltage cable with cross-linked polyethylene insulation XLPE and mechanical protection – XHE 85, XHE 85-A

Standard: SRPS N.C5.230
DIN VDE 0276-620; HD 620 S2; IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION
Conductor: multi-core annealed copper conductor class 2, (XHP 85) or aluminium
(XHP 85-A), according to SRPS N.C0.015
(IEC 60228).

Power medium voltage cables with PVC insulation – PHP 48, PHP 48-A

Standard: SRPS N.C5.220
DIN VDE 0276-620; HD 620 S2
IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21kV
CONSTRUCTION:
Conductor: multi-core conductor class 2, copper PHP 48 or aluminium conductor
PHP 48-A, according to SRPS N.C0.015,
IEC 60228.

Power medium voltage cables with PVC insulation – PHP 81, PHP 81-A

Standard: SRPS N.C5.220
DIN VDE 0276-620; HD 620 S2
IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION:
Conductor: multi-core copper conductor class 2 copper PHP 81 (NYSEYBY) or aluminum conductor PHP 81-A (NAYSEYBY), according to SRPS N.C0.015, IEC 60228.
Inner semi-conductive layer

Power medium voltage cables with PVC insulation – PHP 84, PHP 84-A

Standard: SRPS N.C5.220
DIN VDE 0276-620; HD 620 S2
IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION:
Conductor: multi-core annealed conductor
class 2, copper PHP 84 (NYSEYRGY) or aluminium PHP 84-A (NAYSEYRGY)
according to SRPS N.C0.015, IEC 60288.

Power medium voltage cables with PVC insulation – PHP 85, PHP 85-A

Standard: SRPS N.C5.220
DIN VDE 0276-620; HD 620 S2
IEC 60502-2
Nominal voltage U0/U: 6/10 kV
Test voltage: 21 kV
CONSTRUCTION:
Conductor: multi-core annealed conductor
class 2, copper PHP 85 or aluminium PHP 85-A
according to SRPS N.C0.015, IEC 60228.