Outdoor telecommunication cables
Showing all 12 results
Filled low-frequency cable connecting cable
Standard: TU ZJ PTT 02-13580
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of
0,8 mm; 0,9 mm and 1,2 mm, class 1 (EN 60228)
Insulation: foamed polyethylene with a thin layer of solid polyethylene, foam-skin PE (EN 50290-2-23)
Filled low-frequency cable connecting cable with mechanical protection
Standard: TU ZJ PTT 02-13580
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of
0,8 mm; 0,9 mm and 1,2 mm, class 1 (EN 60228)
Insulation: foamed polyethylene with a thin layer of solid polyethylene, foam-skin PE (EN 50290-2-23).
Filled low-frequency cable subscriber cable – TK 39(G)M
Standard: TU ZJ PTT 02-7833
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of
0,4 mm; 0,6 mm and 0,8 mm, class 1
(EN 60228)
Insulation: solid PE (EN 50290-2-23)
Filled low-frequency subscriber cable with mechanical protection
Standard: TU ZJ PTT 021-14566
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of 0,4 mm; 0,6 mm and 0,8 mm, class 1
(EN 60228)
Insulation: foamed polyethylene with a thin layer of solid polyethylene, foam-skin PE
(EN 50290-2-23).
Filled low-frequency subscriber cable with screen of aluminum wires
Standard: TU ZJ PTT 021-14566
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of 0,4 mm; 0,6 mm and 0,8 mm, class 1
(EN 60228)
Insulation: foamed polyethylene with a thin layer of solid polyethylene, foam-skin PE
(EN 50290-2-23)
Low-frequency subscriber cable with double pe sheath
Standard: TU ZJ PTT 02-6675
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of 0,4 mm; 0,6 mm and 0,8 mm, class 1,
(EN 60228)
Insulation: solid PE (EN 50290-2-23)
Mining telecommunication, signal and signal-telecommunication cable
Standard: SRPS N.C4.015
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of
0,8 mm and 1,4 mm, class 1 (EN 60228)
Insulation: solid PE, type 2YI1 acc. to VDE 0207
(EN 50290-2-23)
COLOUR CODE:
SIGNAL CABLES:
The starting signal core is blue color and all the others are gray color.
Self-supporting low-frequency telephone subscriber cable
Standard:
TU ZJ PTT 02-10157+02-11110
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of
0,6 mm and 0,8 mm, class 1 (EN 60228)
Insulation: solid PE (EN 50290-2-23)
Telephone low-frequency outdoor cable
Standard: VDE 0816
CONSTRUCTION:
soft annealed copper wire diameter of 0,4 mm;
0,6 mm and 0,8 mm, class 1 (EN 60228)
Insulation: solid PE
(EN 50290-2-23)
Twisting elements: cores stranded to star-quads;
5 quads to lay up; bundles to lay up
Telephone outdoor jelly filled low-frequency cable
Standard: DIN VDE 0816
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of 0,4 mm; 0,6 mm and 0,8 mm, class 1 (EN 60228)
Insulation: solid PE type (EN 50290-2-23)
Twisting elements: 4 cores to star-quads stranded;
5 quads to lay up; bundles to lay up
Telephone railway low-frequency cable with inductive protection
Standard:
TECHNICAL SPECIFICATION
OF SLOVENIAN RAILWAYS
CONSTRUCTION:
Conductor: soft annealed copper wire diameter of
1,2 mm, class 1 (EN 60228)
Insulation: foamed polyethylene with a thin layer of solid polyethylene, foam-skin PE
(EN 50290-2-23).
Twisting elements: star quads