Standard:
JŽS S2.013; VDE 0816
CONSTRUCTION:
Symetrical high-frequency quad (VF)
Conductor: soft annealed copper wire of 1,2 mm class 1
Insulation: paper cord and paper tape
Low-frequency quads (NF)

Category: Railway cables
Share:
  • Description
Description

Standard:
JŽS S2.013; VDE 0816
CONSTRUCTION:
Symetrical high-frequency quad (VF)
Conductor: soft annealed copper wire of 1,2 mm class 1
Insulation: paper cord and paper tape
Low-frequency quads (NF)
Conductor: soft annealed copper wire of
0,9 mm diameter, class 1
Insulation: paper cord and paper tape
Twisting elements:
– Symmetrical quad diameter of 1,2 mm,
– Low-frequency star quads diameter of 0,9 mm

Cable core: concentric stranded (see cross section)
Adjacent layers have the opposite direction of twisting.
Core wrapping: at least one layer of four paper tapes, with an overlap. It is allowed one carbonized or metallised paper tape over the last paper tape.
Inductive protection: smooth, seamless aluminium sheath, aluminum minimum purity 99,5%.
Minimal thickness of Al sheath is such to satisfy the requirements of the reduction factor.

Protection from mechanical damage and corrosion:
The inner protective layer below the two steel tapes coated with a compound.
Thickness of steel tapes is 1,0 mm with max. gap of 1/3 width of the tape.
The outer protective layer above the two steel tapes coated with a compound.
Outer sheath: PE sheath, black colour
(UV protection)

APPLICATION:
Railway signal and telecommunication cables designed for laying along a railway line electrified single-phase system 25 kV, 50 Hz and DC direct current system 3000 V.

coptech beograd

Tel: +381 11 328 25 10
Tel/Fax: +381 11 328 25 41
E-mail: coptech@sbb.rs | info@coptech.rs

Main address: Peke Pavlovića 16, 11000 Beograd
Office address: Kneza Mihailova 21/10, 11000 Beograd
Business unit address in Jagodina: Kneza Lazara 187, 35000 Jagodina

MB:20311819 | PIB:105087097
Accounts info:
160-278653-63 Banca Intesa ad
205-159358-30 Komercijalna banka

Copyright © 2021. All Rights Reserved / politika privatnosti i pravila korišćenja
izrada sajta
  • Home
  • About Us
  • Our products
    • Cables and Conductors
    • Copper wire
    • Copper ropes
    • Copper pipes
    • Others products
  • References
  • ISO certification
  • Donations/sponsorship
  • Gallery
  • Contact
We use cookies to improve your experience on our website. By browsing this website, you agree to our use of cookies.
Accept
Start typing to see products you are looking for.