Standard:
ISO/IEC 11801, IEC 61156-5; EN 50173,
EN 50288, TIA/EIA-568
CONSTRUCTION:
Conductor: copper (bare, solid), diameter
0,51 mm, AWG24, cl. 1
Insulation: solid polyethylene (PE), outer diameter, approx. 1,1 mm
Twisting elements: two cores twisted in pairs
Cable core: 4 stranded pairs
Common screen: Al laminated plastic foil + braid of tinned Cu drain wires
Outer sheath: PVC or halogen-free (LSZH, LSOH, FRNC), external diameter, approx.: 6,4-6,6 mm
Sheath color: dark grey (PVC) or orange (LSZH)
Behavior in fire:
Self-extinguishing cable acc. to IEC 60332-1/
EN 60332-1/VDE 0482-332-1
LSZH (FRNC-C) version, additionally:
halogen-free acc. to IEC 60754-1;
non-corrosive combustion gases acc. to
IEC 60754-2;
minimal smoke release acc. to IEC 61034-2;
resistant to flame propagation acc. to
IEC 60332-3 (LSZH-FR, LSFROH, FRNC-C)
APPLICATION:
Cable applied in structured cabling system of class D for high-speed data and voice transmission, at primary, secondary (vertical) and tertiary (horizontal) level.
Standardized for application up to 240 MHz
(in certain configurations even up to 300 MHz).
Can be laid in cable canals.
The permissible temperature range:
– during installation: 0°C up to +50°C
– operating temperature: -20°C up to +60°C
Minimal inner bending radius:
– fixed: 4D (25 mm)
– at installation: 8D (50 mm)
(D – external cable diameter)
Maximal tensile strength: 120 N