Standard: SRPS N.C3.350 for ŽEpN
UIC 895 for BT i HT
Nominal voltage U0/U: 750V, 1500V, 3000V
Test voltage: 2 kV; 6 kV; 12 kV
CONSTRUCTION
Conductor: copper conductor class 5 and
class 6 (IEC 60228; SRPS N.C0.015).
Separator: suitable tape.
Insulation: rubber compound based on EPR rubber.
Sheath: based on chlorosulphonated polyethylene rubber, oil, fat and fuel resistant,
flame retardant.
Sheath colour black.
Flame retardant: IEC 60332-1
Oil resistant: DIN VDE 0472-803, metod A
APPLICATION
Cable is used in electrical vehicles for current
circuits, for current circuits for heating and
control, as well as for lighting.
Permissible conductor temperature:
– max operating temperature +90°C
– in short circuit (max 5 s), max. +250°C
Permissible environment temperature:
– at laying and handling, min.: -20°C.
– in use min. -40°C.
BENDING RADIUS (min.):
Smallest bending radius: 6D
(D – cable diameter)