Standard:
DIN VDE 0250-814
Nominal voltage
U0/U: 0,6/1 kV
Test voltage: 2,5 kV
CONSTRUCTION
Conductor: tinned copper conductor class 5 Insulation: based on EPR rubber 3GI3 or GI1 acc. to DIN VDE 0207 part 20, concentrically stranded cores in layers.
Inner sheath: based on synthetic rubber GM1b
acc. to DIN VDE 0207 part 21.
Torsion protection: braid with cord
Sheath: rubber compound on poly-chloroprene basis (CR) (= Neoprene), i.e. 5GM2 or 5GM3 acc. to DIN VDE 0207 part 21. Sheath colour black.
Oil resistant: DIN VDE 0472-803, metod A
Flame-retardant: according to IEC 60332-1-2
APPLICATION:
The cable is intended for connecting mobile
devices with a large mechanical stresses in dry, wet and huge humidity areas and outdoors.
The cable is very convenient if there is a strain due rolling.
Permissible conductor temperature:
– max operating temperature +90°C,
– in short circuit (max 5 s), max +250°C.
Permissible environment temperature:
– mobile from -25C to +50C,
– fixed laying from -40C to +50C.
Smallest bending radius: 5D
(D – cable diameter)
Maksimalna sila naprezanja:
– statička: 15 N/mm²
– dinamička: 30 N/mm²