Standard:
DIN VDE 0250-602
Nominal voltage
U0/U: 0,6/1 kV; 1,8/3 kV; 3,6/6 kV
Test voltage: 2,5 kV; 6 kV; 11 kV
CONSTRUCTION
Conductor: tinned copper conductor,
class 1 and class 2 for NSGAöu and tinned copper conductor class 5 for NSGAFöu.
Separator: suitable tape, for 6 kV semiconductive tape.
Insulation: rubber compound based on EPR rubber (3GI3).
Sheath: based on polychloroprene rubber
(5GM3), oil, fat and fuel resistant; flame
retardant.
Sheath colour black.
Oil resistant: DIN VDE 0472-803, metod A
Flame-retardant: according to IEC 60332-1-2
APPLICATION:
Cable is used in electrical vehicles for current
circuits, for current circuits for heating and
control, as well as for lighting.
Permissible conductor temperature:
– max operating temperature +90°C,
– in short circuit (max 5 s), max +250°C.
Permissible environment temperature:
– at laying, min. -20C,
– in use, min. -40C
Smallest bending radius: 6D
(D – cable diameter)