Standard: DIN VDE 0266
Nominal voltage U0/U: 0,6/1 kV
Test voltage: 4 kV
CONSTRUCTION
Conductor: solid annealed copper conductor, class 1 or multi wire class 2, according to
DIN VDE 0295, IEC 60228
Wrapping: Fiber glass textile tape (mica tape)
Insulation: cross-linked halogen-free polymer, HXI1 acc. to DIN VDE 0266
Core: concentrically stranded cores, colour marked acc. to HD 308 S2/VDE 0293-308, with or without protective yellow-green conductor
Filler: halogen free layer over stranded cores.
Sheath: halogen free corsslinked compound
base on polyolefin (HXM1, prema
DIN VDE 0266).
Sheath colour: orange
Flame retardant: IEC 60332-1
No flame propagation: IEC 60332-3 cat. C
Insulation integrity: IEC 60331
Halogen-free: IEC 60754-1
Non-corrosive combustion gases: IEC 60754-2
Low smoke density: IEC 61034-2
Function integrity: DIN VDE 4102/12 of electrical cable system for a period of 30-90 min.
APPLICATION
Cable with improved characteristics and functionality of insulating in fire supplies power to the device 180 min. These cables are intended for installation in the object where there are rather large requirements for safety of people and property – not spreading the fire, not producing dangerous smoke – it is built in buildings where making evacuation is difficult and where is very important to prevent fast spreading of a fire.
Permissible conductor temperature:
– max operating temperature +90°C
– in short circuit (max 5 s), max +250°C
Permissible environment temperature:
– at laying and handling, min +5C to +50C
BENDING RADIUS (min.):
– single core cables 15D; (D – cable diameter)
– multi-wires cable 12D
Halogen free cable with improved characteristics in fire – NHXHX FE-180 E30/E90
Standard: DIN VDE 0266
Nominal voltage U0/U: 0,6/1 kV
Test voltage: 4 kV
CONSTRUCTION
Conductor: solid annealed copper conductor, class 1 or multi wire class 2, according to
DIN VDE 0295, IEC 60228
Wrapping: Fiber glass textile tape (mica tape)
Insulation: cross-linked halogen-free polymer, HXI1 acc. to DIN VDE 0266
Core: concentrically stranded cores, colour marked acc. to HD 308 S2/VDE 0293-308, with or without protective yellow-green conductor
Filler: halogen free layer over stranded cores.
Tel: +381 11 328 25 10
Tel/Fax: +381 11 328 25 41
E-mail: coptech@sbb.rs | info@coptech.rs
Main address: Peke Pavlovića 16, 11000 Beograd
Office address: Kneza Mihailova 21/10, 11000 Beograd
Business unit address in Jagodina: Kneza Lazara 187, 35000 Jagodina
MB:20311819 | PIB:105087097
Accounts info:
160-278653-63 Banca Intesa ad
205-159358-30 Komercijalna banka