Show 36

All dielectric self supporting cable ADSS, central unitube construction

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm) according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2);
b) cladding: Silicon glass (SiO2)

All dielectric self supporting cable ADSS, concentrically stranded

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm) according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2);

All dielectric self supporting cable ADSS, concentrically stranded

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm) according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2);

Fiber optic cable, outdoor, with corrugated steel tape

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm) according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2)

Installation fiber optic cable, with HFFR sheath, non metalic, Duplex

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
MM – multimode 50/125 µm or 62,5/125 µm
according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2);

Installation fiber optic cable, with HFFR sheath, non metalic, Simplex

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm) G.657A1/A2 according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2);

Non metalic fiber optic cable, concentrically stranded, jelly filled

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers
(50/125 µm or 62,5/125 µm)

Non metalic fiber optic cable, concentrically stranded, jelly filled, with rodent protection-TO SM 03 CMARN, A-DF(ZN)B2Y

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm)
according to ITU-T Recommendation

Non metalic fiber optic cable, concentrically stranded, jelly filled, with rodent protection-TO SM 03 CMRN, A-DF(BN)2Y

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibres:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm)
according to ITU-T Recommendation

Non metalic outdoor fiber optic cable, central unitube construction, with rodent protection

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm)
ITU-T Recommendation

Non metalic outdoor fiber optic cable, concentrically stranded, dry filled

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm)
according to ITU-T Recommendation

Non metalic outdoor fiber optic cable, concentrically stranded, dry filled, with rodent protection

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm) according to ITU-T Recommendation

Non metalic, central unitube construction, outdoor fiber optic cable

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125)
according to ITU-T Recommendation

Self supporting, fiber optic cable, central unitube construction, with steel messinger, outdoor

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125) according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2);

Self supporting, fiber optic cable, concentrically stranded, with steel messinger, outdoor

Standard: IEC 60794; VDE 0888
CONSTRUCTION:
Optical fibers:
SM – single mode optical fibers (9/125 µm)
(G.652D, G.655, G.657A1/A2)
MM – multi mode optical fibers (50/125 or 62,5/125 µm) according to ITU-T Recommendation
Material of fibers:
a) core – Silicon glass: (SiO2) doped with Germanium Dioxide (GeO2);